The Comparison of Ultrasonography Guided Mammotome Biopsy between 8 and 11 Gauge Probe
Published Online: Sep 30, 2005
Abstract
The goal of this study was to compare the diagnostic accuracy, complication rate between 11 and 8 gauge Mammotome probe during ultrasound-guided Mammotome biopsy.
Sixty eight patients who showed breast mass in sonography were included in this study. Statistical comparisons between the 11 and 8 gauge group were done.
75 biopsies were performed using the Mammotome biopsy system guided by sonography. 63 LESIONS(84.0%) had benign pathology and 12 lesions(16.0%) were malignant. 49(65.3%) of these biopsies were performend with the 11-gauge Mammotome probe, and 26(34.7%) with the 8-gauge probe. Complications such as pain, bleeding , hematoma and skin discoloration were compared between 11 and 8 gauge group. There were nostatistically significant differences in complications such as pain, bleeding, hematoma and skin discoloration. All complications had no significant difference between 11 gauge group and 8 gauge group.
Metrics
QR Code of this Article:
Related Articles
Invasive Lobular Carcinoma: Detection and Multiplicity with Multimodalities
Ewha Med J 2018;41(2):27-34.
A Clinical Study of Early Gastruc Cancer
Ewha Med J 1990;13(3):173-179.
A Clinical Analysis of the Traumatic Injuries of the Liver
Ewha Med J 1983;6(4):291-298.
Imaged-Guided Percutaneous Fine-Needle Aspitation Biopsy
Ewha Med J 1995;18(4):475-479.
Comparison of Abdominal and Vaginal Sonography in Normal and Abnormal Early Pregnancy
Ewha Med J 1991;14(3):257-265.