• Contact us
  • E-Submission
ABOUT
BROWSE ARTICLES
JOURNAL POLICIES
FOR CONTRIBUTORS

Articles

Page Path

Original Article

Measurement of Sebum Secretion Using a Lipid Absorbent Tape

The Ewha Medical Journal 1992;15(4):347-351. Published online: July 24, 2015

Department of Dermatology, College of Medicine, Ewha Womans University, Korea.

Copyright © 1992. Ewha Womans University School of Medicine

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 26 Views
  • 0 Download
prev next
  • A lipid absorbent tape(Sebutape®)is a new device for measurement of skin surface lipid I have tested the utility of lipid absorbent tape method for the measurement of sebum secretion rates of 20 healthy adult males comparing with conventional hexane extraction technique. The results are as follows :
    1) The average amount of total sebum collected using lipid absorbent tape technique and hexane extraction technique were 109.20±43.89µg/3hrs/cm2 and 113.94±47.l2µg/3hrs/cm2 respectively. and the correlated well(r=0.93).
    2) The 2 techniques were in good accord with reference to their efficacy in collection of free fatty acid(r=0.55). triglyceride(r=0.76). wax and cholesterol esters(r=0.91), and squlaene (r=0.89) from the surface of the skin, but the correlation of cholesterol(r=0.17) was poor.
    3) Lipid absorbent tape furnished a good means of visualization of the droplets produced by individual follicles.
    Above results indicate that the lipid absorbent tape provide a new convenient technique for the measurement of sebum secretion rate and quantitation of components of skin surface lipids.

Figure & Data

References

    Citations

    Citations to this article as recorded by  

      Download Citation

      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:

      Include:

      Measurement of Sebum Secretion Using a Lipid Absorbent Tape
      Ihwa Ŭidae chi. 1992;15(4):347-351.   Published online July 24, 2015
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Measurement of Sebum Secretion Using a Lipid Absorbent Tape
      Ihwa Ŭidae chi. 1992;15(4):347-351.   Published online July 24, 2015
      Close
      Measurement of Sebum Secretion Using a Lipid Absorbent Tape
      Measurement of Sebum Secretion Using a Lipid Absorbent Tape
      TOP