• Contact us
  • E-Submission
ABOUT
BROWSE ARTICLES
JOURNAL POLICIES
FOR CONTRIBUTORS

Articles

Page Path

Original Article

Retinal Changes after Replacement of Vitreous with Perfluorodecalin

The Ewha Medical Journal 1994;17(4):363-369. Published online: December 31, 1994

Department of Ophthalmology, College of Medicine, Ewha Womans University, Korea.

Copyright © 1994. Ewha Womans University School of Medicine

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 27 Views
  • 0 Download
prev next
  • Retinal changes were evaluated after vitreous replacement with perfluorodecalin. Tolerance to this liqued in rabbit eyes was investigated for peiod of 1 month.
    Histologic examination revealed degeneration the loss of the outer segment of the photoreceptors, decreased thickness of the outer retinal layers and in the vitreous These changes were progressed with the longer duration of the intravitreal replacement of perfluorodecalin. From the above resulgts, perfluorodecalin is thought to be unsuttable for the long-term witreous substitute and should be removed from the wyw before the vompletion of surgery.

Figure & Data

References

    Citations

    Citations to this article as recorded by  

      Download Citation

      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:

      Include:

      Retinal Changes after Replacement of Vitreous with Perfluorodecalin
      Ihwa Ŭidae chi. 1994;17(4):363-369.   Published online December 31, 1994
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Retinal Changes after Replacement of Vitreous with Perfluorodecalin
      Ihwa Ŭidae chi. 1994;17(4):363-369.   Published online December 31, 1994
      Close
      Retinal Changes after Replacement of Vitreous with Perfluorodecalin
      Retinal Changes after Replacement of Vitreous with Perfluorodecalin
      TOP