• Contact us
  • E-Submission
ABOUT
BROWSE ARTICLES
JOURNAL POLICIES
FOR CONTRIBUTORS

Articles

Page Path

Original Article

Changes of Peak Inspiratory Airway Pressure and Compliance during One-Lung Ventilation Using Double Lumen Tube and Univent Tube

The Ewha Medical Journal 1999;22(4):273-277. Published online: December 31, 1999

Department of Anesthesiology, College of Medicine, Ewha Womans University, Korea.

Copyright © 1999. Ewha Womans University School of Medicine

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 24 Views
  • 0 Download
prev
  • Objects
    One-lung anesthesia offers advantages during thoracic surgery, but has the disadvantage of causing hypoxemia and affects the respiratory mechanics.
    We investigated the peak inspiratory airway pressure(PIP) and compliance during one-lung ventilation using different tubes.
  • Methods
    In healthy 12 patients undergoing thoracic surgery, left-sided double lumen endobronchial tube was inserted. In 10 patients, Univent tube was inserted and fixed the blocker using the bronchofiberscope. The PIP, compliance, end-tidal CO2 and SpO2 were measured using a Capnomac Ultima® during two-lung and right one-lung ventilation.
  • Results
    During two-lung ventilation, there was no difference between the two groups During one-lung ventilation PIP increased and compliance decreased significantly than two-lung ventilation. In the double lumen tube group, PIP increased significantly and compliance decreased significantly than Univent tube group. There was no significant changes in the end-tidal PCO2 and SpO2.
  • Conclusion
    Univent tube provide lesser changes of PIP and compliance during one-lung anesthesia in supine position than double lumen endobronchial tube.

Figure & Data

References

    Citations

    Citations to this article as recorded by  

      Download Citation

      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:

      Include:

      Changes of Peak Inspiratory Airway Pressure and Compliance during One-Lung Ventilation Using Double Lumen Tube and Univent Tube
      Ihwa Ŭidae chi. 1999;22(4):273-277.   Published online December 31, 1999
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Changes of Peak Inspiratory Airway Pressure and Compliance during One-Lung Ventilation Using Double Lumen Tube and Univent Tube
      Ihwa Ŭidae chi. 1999;22(4):273-277.   Published online December 31, 1999
      Close
      Changes of Peak Inspiratory Airway Pressure and Compliance during One-Lung Ventilation Using Double Lumen Tube and Univent Tube
      Changes of Peak Inspiratory Airway Pressure and Compliance during One-Lung Ventilation Using Double Lumen Tube and Univent Tube
      TOP